What was found
CRACKED FITTING, FLOOR STRUCTURE BS 947, LBL 11, AFT CARGO BAY. REPLACED THE FITTING IAW SRM 51-10-02 ITEM (9) & DWG 149A8103 SHEET 8 REV-. MEASURES OF CRACK IS:0.8310
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACKED FITTING, FLOOR STRUCTURE BS 947, LBL 11, AFT CARGO BAY. REPLACED THE FITTING IAW SRM 51-10-02 ITEM (9) & DWG 149A8103 SHEET 8 REV-. MEASURES OF CRACK IS:0.8310