What was found
FAULT RAISED TO CAPTURE RII LABOR OF CRACK ON WEB INTERCOSTAL LOCATED BTW BS 344 TO BS 360 LBL 10 WL 208.1 AT FWD GALLEY AREA. REPLACED INTERCOSTAL AND FASTENERS LOCATED BTW BS 344 TO BS 360 LBL 10 WL 208.1 AT FWD GALLEY AREA IAW SRM 53-10-15; SRM 51-40-02 AND SRM 51-10-02, ITEM 9, DWG 141A5400, SHEET 46, REV A.