What was found
CRACKED CORRUGATED PLATE TRAILING EDGE LOCATED ORSS 250 AT LT WING. PERFORMED VISUAL INSPECTION IAW SRM 51-10-04-0G-0 ON CORRUGATED PLATE TRAILING EDGE LOCATED ORSS 250 AT LT WING AND NOT FOUND CRACK ONLY BROKEN FASTENER HEAD (2/EA) REMOVED AND INSTALLED FASTENER IAW SRM 51-40-02-0G-0, AND DWG 115A2001, SHEET 29, REV-.