What was found
CRACK ON ANGLE LOCATED FWD FACE BS 500C AT LEVEL STR 26L AT FWD CARGO BAY. REPLACED THE ANGLE AND FASTENERS LOCATED FWD FACE BS 500C AT LEVEL STR 26L IAW SRM 51-40-02-0G-0 AND DWG 143A7505; SHEET 82; REV.-.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK ON ANGLE LOCATED FWD FACE BS 500C AT LEVEL STR 26L AT FWD CARGO BAY. REPLACED THE ANGLE AND FASTENERS LOCATED FWD FACE BS 500C AT LEVEL STR 26L IAW SRM 51-40-02-0G-0 AND DWG 143A7505; SHEET 82; REV.-.