What was found
CORROSION ON WEB AT BS 1018 LBL 1 WL 208. NO ALLOWABLE ENTRIES FOUND THEREFORE SHEAR WEB DAMAGE TO BE REMOVE IAW SRM 51-10-02-0G-0 AND SENT TO ENGINEERING FOR FURTHER REPAIR INSTRUCTIONS. REMOVED CORROSION ON WEB AT BS 1018 LBL 1 WL 208 1'X1' AREA IAW SRM 51-10-02-0G-0. REMOVED 1EA FASTENER TO FOM BS 1018 LBL 1 WL 208 IAW SRM 51-40-02-0G-0. INSTALLED ONE FASTENER IAW SRM 51-40-02-0G-0 & SRM 147A5600 REV B. ACCOMPLISHED HFEC INSP OF ONE HOLE WITHIN REWORKED AREA IAW NDTM PART 6 CHAPTER 51-00-00 PROCEDURE 16. NO CRACKS NOTED. APPLIED CHEMICAL CONVERSION COAT & PRIMED AREA IAW SRM 51-20-01 AND SOPM 20-41-02. REMOVED & TREATED CORROSION ON WEB IAW SRM 51-10-02-0G-0, AND EA 26-153-01349.