What was found
CRACKED ANGLE, BS 500H, STR 26L. REPLACED ANGLE AND FASTENERS IAW SRM 51-10-02, STEP 9, SRM 51-40-02, AND DWG 143A7505, SHEET 138, REV -.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACKED ANGLE, BS 500H, STR 26L. REPLACED ANGLE AND FASTENERS IAW SRM 51-10-02, STEP 9, SRM 51-40-02, AND DWG 143A7505, SHEET 138, REV -.