What was found
OTS - ATB- ELEC. STAB TRIM FAIL ON CLIMB AROUND 1000 FT AGL._ REMOVED AND REPLACED STABILIZER TRIM MOTOR IAW AMM 27-41-71. OPS CHKD GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
OTS - ATB- ELEC. STAB TRIM FAIL ON CLIMB AROUND 1000 FT AGL._ REMOVED AND REPLACED STABILIZER TRIM MOTOR IAW AMM 27-41-71. OPS CHKD GOOD.