What was found
CORROSION ON RT FLOOR SIDEWALL SUPPORT AT FCB WL 153. BS 492.4+2, BS 500+2; +6. REMOVED AND REPLACED RT FLOOR SIDEWALL SUPPORT IAW SRM 51-40-02-0G-0, AND DWG 143A0080, REV -.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON RT FLOOR SIDEWALL SUPPORT AT FCB WL 153. BS 492.4+2, BS 500+2; +6. REMOVED AND REPLACED RT FLOOR SIDEWALL SUPPORT IAW SRM 51-40-02-0G-0, AND DWG 143A0080, REV -.