LEFT STUB BEAM STRAP, LOWER, FWD FASTENER HOLE FOUND CRACKED AT BS 639 AT INBD LAYER. OK TO CONTINUE IAW SRM 51-40-02-0G-0-A00729. FASTENER INSTALLATION AND REMOVAL. REPLACED RT STUB BEAM STRAP AT BS 639, LBL 45 & RESTORED FINISHES IAW SRM 51-40-02-0G-0, SRM 51-40-05-0G-0, SRM 51-20-01-0G-0, DWG 144A7301, REV A, DWG 144A1705, REV E, AMM 28-11-00-00-804, AMM 28-11-00-300-804, AMM 51-21-00-160-801, AMM 51-21-72-370-804, AMM 28-11-00-300-804, & SOPM 20-50-19.