What was found
CORRODED FLOOR SUPPORT, BTWN BS 947.5 + 4 INCHES, LBL 19, WL 208.1 IN THE AFT GALLEY AREA. REPLACED FLOOR SUPPORT IAW SRM 51-40-02, SRM 51-10-02, ITEM 9, & DWG 147A5650, SHT 55, REV A.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORRODED FLOOR SUPPORT, BTWN BS 947.5 + 4 INCHES, LBL 19, WL 208.1 IN THE AFT GALLEY AREA. REPLACED FLOOR SUPPORT IAW SRM 51-40-02, SRM 51-10-02, ITEM 9, & DWG 147A5650, SHT 55, REV A.