What was found
RIGHT AFT OVERWING EMERGENCY LIGHT INOPERATIVE, OK TO CONTINUE ON MEL 33-51-02 SP1. RELAMPED RT AFT EXTERIOR OVERWING ESCAPE LIGHT. REPLACED POWER SUPPLY M1671 BATTERY PACK AND RESECURED GROUND WIRE W4142-0625-20 IN GROUND BLOCK GD3806-DC IAW AMM 33-51-06 33-51-04 SWPM 20-20-11 WDM 33-51-14. SHOULD READ: RELAMPED RT. AFT EXTERIOR OVERWING ESCAPE LIGHT REPLACED POWER SUPPLY M1671 BATTERY PACK AND RESECURED GROUND WIRE W4142-0252-16 IN GROUND BLOCK GD3802-DC IAW AMM 33-51-06 33-51-04 SWPM 20-20-11 WDM 33-51-14.