What was found
CORROSION ON RT FLOOR TO SIDEWALL SUPPORT, BS 787 - 727D, WL 157.79. R & R WITH A NEW SIDEWALL SUPPORT IAW SRM 51-40-02-0G-0, AND DWG 146A7500, REV -.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON RT FLOOR TO SIDEWALL SUPPORT, BS 787 - 727D, WL 157.79. R & R WITH A NEW SIDEWALL SUPPORT IAW SRM 51-40-02-0G-0, AND DWG 146A7500, REV -.