What was found
CORROSION FLOOR STRUCTURE STIFFENER ON BS 947 AT LEVEL LBL 52 AND WL 208.1 AT AFT GALLEY AREA 2026-456142 REPLACED STIFFENER (INTERCOSTAL) AND FASTENERS LOCATED BTW BS 947 TO BS967 AT LEVEL LBL 52 AND WL 208.1 AT AFT GALLEY AREA IAW B737-8 SRM-51-40-02 AND DWG NO. 147A5650 SHEET 55 REV. A. SEE INDIVIDUAL SIGN OFF BELOW. REPLACED STIFFENER (INTERCOSTAL) AND FASTENERS LOCATED BTW BS 947 TO BS967 AT LEVEL LBL 52 AND WL 208.1 AT AFT GALLEY AREA IAW B737-8 SRM-51-40-02 AND DWG NO. 147A5650 SHEET 55 REV. A. SEE INDIVIDUAL SIGN OFF BELOW.