What was found
CRACK WEB - INTERCOSTAL FLOOR STRUCTURE BTW STA 277 TO STA 294.5 AND BL 0 AT FWD GALLEY AREA 2026-446715 REPLACED WEB - INTERCOSTAL AND FASTENERS ON FLOOR STRUCTURE BTW STA 277 TO STA 294.5 AND BL 0 AT FWD GALLEY AREA IAW B737-800 SRM 51-40-02 SRM 51-10-02 ITEM 9 AND DWG 141A5400 SHEET:20 REV-. SEE INDIVIDUAL SIGN OFF BELOW. REPLACED WEB - INTERCOSTAL AND FASTENERS ON FLOOR STRUCTURE BTW STA 277 TO STA 294.5 AND BL 0 AT FWD GALLEY AREA IAW B737-800 SRM 51-40-02 SRM 51-10-02 ITEM 9 AND DWG 141A5400 SHEET:20 REV-. SEE INDIVIDUAL SIGN OFF BELOW.