What was found
CORROSION FOUND IN (MULTIPLE SPOTS) ON TOP AFT (WET AREA) FLOOR STRUCTURE AT RBL 18 BS 1006 - BS 1014 WL 208. REMOVED AND REPLACED TENSION STRAP BS 1016 - 1028, RBL 18, WL 208 IAW SRM 51-40-02-0G-0 AND SRM 147A5730 REV: C.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FOUND IN (MULTIPLE SPOTS) ON TOP AFT (WET AREA) FLOOR STRUCTURE AT RBL 18 BS 1006 - BS 1014 WL 208. REMOVED AND REPLACED TENSION STRAP BS 1016 - 1028, RBL 18, WL 208 IAW SRM 51-40-02-0G-0 AND SRM 147A5730 REV: C.