What was found
CORROSION FOUND IN (MULTIPLE SPOTS) ON TOP AFT (WET AREA) FLOOR STRUCTURE AT LBL 3 BS 1006 - BS 1010 WL 208. REMOVED AND REPLACED TENSION STRAP BS 1006-1024 LBL 3 IAW SRM 51-40-02-0G-0 AND SRM 147A5600, REV B.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FOUND IN (MULTIPLE SPOTS) ON TOP AFT (WET AREA) FLOOR STRUCTURE AT LBL 3 BS 1006 - BS 1010 WL 208. REMOVED AND REPLACED TENSION STRAP BS 1006-1024 LBL 3 IAW SRM 51-40-02-0G-0 AND SRM 147A5600, REV B.