What was found
AFT GALLEY AREA EMERGENCY EXIT LIGHTS BURN AT SEVERAL PLACES, LT 2 AND RT 2 DOORS, RT OVER WING EXIT AND EXTERIOR R2 DOOR. REPLACED EMERGENCY BATTERY PACK OF THE POWER SUPPLY M1672 AT AFT GALLEY AREA IAW AMM 33-51-06-960-805. TEST IS OK SEE INDIVIDUAL SIGN OFF BELOW COMPLETED TASK SEE INDIVIDUAL SIGN OFF BELOW.