What was found
ELONGATED HOLE ON CORRUGATED PLATE LOCATED ORSS 320 TRAILING EDGE, RT WING. REPLACED CORRUGATED PLATE, DID NOT FIND ALLOWABLE DAMAGE LIMITS IN SRM 57-51-02-1A-1, ALLOWABLE DAMAGE 1, SRM 51-10-02, ITEM 9, & DWG 115A3700, SHEET 96, REV - .