What was found
FOUND CORROSION ON FLOOR SUPPORT, BS 328+5 - 328+12, LBL 22, WL 208. REMOVED AND REPLACED THE FLOOR SUPPORT IAW SRM 51-40-02-0G-0, AND DWG 141A5730, REV A. NUT PLATE DEBONDED AND TWO FASTENERS ARE NOT INSTALLED AT BS 344, LBL 22. AFTER INTERCOSTAL INSTALLED 2 FASTENERS AT BS LBL 22 AND 3 NUTPLATES INSTALLED IAW SRM 51-40-02-0G-0.