What was found
CORROSION FLOOR SUPPORT LOCATED BS 947.4 PLUS 1 INCH, RBL 50, WL 208.1 IN THE AFT GALLEY AREA. REPLACED FLOOR SUPPORT IAW SRM 51-10-02, ITEM 8, SRM 51-40-02 AND DWG 147A5650 SHEET 105 REV-.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FLOOR SUPPORT LOCATED BS 947.4 PLUS 1 INCH, RBL 50, WL 208.1 IN THE AFT GALLEY AREA. REPLACED FLOOR SUPPORT IAW SRM 51-10-02, ITEM 8, SRM 51-40-02 AND DWG 147A5650 SHEET 105 REV-.