What was found
AFT SERVICE DOOR THRESHOLD CORRODED, FOUND ON Z ANGLE IN MULTIPLE AREAS FROM BS 967-986.5. FOUND TO BE OUT OF LIMITS IAW SRM 53-7-15-1A-1. REMOVED THE ANGLE IAW SRM 51-40-02. LOCATED AND DRILLED IAW SRM 51-40-02 AND DWG 147A8501. COUNTERSUNK ALL FASTENER HOLES IAW SRM 51-40-08, SRM 51-40-02, & DWG 147A8501. INSTALLED, & APPLIED FILLET SEAL ON AFT SVC DOOR ANGLE IAW AMM 51-22-00.