What was found
CORROSION FOUND ON AFT WET AREA FLOORBEAM AT BS 987, RBL 42, WL 208. REPAIRED THE UPPER TEE ON THE FLOORBEAM IAW SRM 53-70-51-2R-6, REPAIR 6.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FOUND ON AFT WET AREA FLOORBEAM AT BS 987, RBL 42, WL 208. REPAIRED THE UPPER TEE ON THE FLOORBEAM IAW SRM 53-70-51-2R-6, REPAIR 6.