What was found
CRACK INDICATION ON STUB FRAME BTWN BS 294.5 & 296.5, STRINGER 8R & 9R ON THE FWD GALLEY DOOR AREA . REPLACED THE STUB FRAME IAW SRM 51-10-02-0G-0, ITEM 9, SRM 51-40-02-0G-0, DWG 141A8370, SHT 10, REV -, & DWG 141A8380, SHT 21, REV -.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK INDICATION ON STUB FRAME BTWN BS 294.5 & 296.5, STRINGER 8R & 9R ON THE FWD GALLEY DOOR AREA . REPLACED THE STUB FRAME IAW SRM 51-10-02-0G-0, ITEM 9, SRM 51-40-02-0G-0, DWG 141A8370, SHT 10, REV -, & DWG 141A8380, SHT 21, REV -.