What was found
CORROSION ON THE FLOOR SUPPORT AT NUTPLATE HOLES, BS 947+11& 15, LBL 16, WL 208. REMOVED AND INSTALLED THE FLOOR SUPPORT BTWN BS 947 - 967, LBL 16, WL 208 IAW SRM 51-40-02, & DWG 147A5650, REV A.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON THE FLOOR SUPPORT AT NUTPLATE HOLES, BS 947+11& 15, LBL 16, WL 208. REMOVED AND INSTALLED THE FLOOR SUPPORT BTWN BS 947 - 967, LBL 16, WL 208 IAW SRM 51-40-02, & DWG 147A5650, REV A.