What was found
DURING SCHEDULED 1/2 D-CHECK, FOUND AFT GALLEY FLOOR BEAM CORRODED AT SCREW HOLES, UPPER AND LOWER SURFACES AT AFT FLANGE AT BS 1006, LBL 15, 19 AND 23. INSTALLED REPAIR STRAPS PER SWA RA 1-253-1411.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED 1/2 D-CHECK, FOUND AFT GALLEY FLOOR BEAM CORRODED AT SCREW HOLES, UPPER AND LOWER SURFACES AT AFT FLANGE AT BS 1006, LBL 15, 19 AND 23. INSTALLED REPAIR STRAPS PER SWA RA 1-253-1411.