What was found
DURING SCHEDULED 1/2 D-CHECK, FOUND FLOORBEAM STRAP AT BS 430, LBL 18.25, TO RBL 19 CORRODED AROUND NUT PLATE HOLES, TOP AND BOTTOM. REPAIRED PER BOEING SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED 1/2 D-CHECK, FOUND FLOORBEAM STRAP AT BS 430, LBL 18.25, TO RBL 19 CORRODED AROUND NUT PLATE HOLES, TOP AND BOTTOM. REPAIRED PER BOEING SRM.