What was found
DURING SCHEDULED 1/2 D-CHECK, FOUND CORRODED FLOORBEAM AT BS 987, RBL 35 AROUND FLOORBOARD SCREW HOLE, BS 987 FASTENER HOLE TOP FWD SIDE RBL 39 AND BS 987 FASTENER HOLE TOP FWD SIDE RBL 42.5. REPAIRED PER SWA RA 1-353-1830.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED 1/2 D-CHECK, FOUND CORRODED FLOORBEAM AT BS 987, RBL 35 AROUND FLOORBOARD SCREW HOLE, BS 987 FASTENER HOLE TOP FWD SIDE RBL 39 AND BS 987 FASTENER HOLE TOP FWD SIDE RBL 42.5. REPAIRED PER SWA RA 1-353-1830.