What was found
DURING SCHEDULED 1/2D CHECK, FOUND STUB FRAME CRACKED AT UPPER FWD CORNER OF SERVICE DOOR, BS 294.5. REPAIRED PER SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED 1/2D CHECK, FOUND STUB FRAME CRACKED AT UPPER FWD CORNER OF SERVICE DOOR, BS 294.5. REPAIRED PER SRM.