What was found
DURING SCHEDULED SERVICE CHECK, FOUND FWD SECTION OF EMERGENCY FLOOR TRACK LIGHTING INOP. SPLICED WIRE TO LAMP ASSY PER MM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED SERVICE CHECK, FOUND FWD SECTION OF EMERGENCY FLOOR TRACK LIGHTING INOP. SPLICED WIRE TO LAMP ASSY PER MM.