What was found
DURING SCHEDULED 1/4D CHECK, FOUND THROUGH EDDY CURRENT INSPECTION A CRACK INDICATION ON UPPER HINGE CUTOUT ON L-1 DOOR. REPAIRED PER SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED 1/4D CHECK, FOUND THROUGH EDDY CURRENT INSPECTION A CRACK INDICATION ON UPPER HINGE CUTOUT ON L-1 DOOR. REPAIRED PER SRM.