What was found
DURING SCHEDULED RON CHECK, FOUND CORROSION AT FLOORBEAM, BS 986.5, FROM CENTER TO RT END. REMOVED AND REPLACED FLOORBEAM SECTION PER SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED RON CHECK, FOUND CORROSION AT FLOORBEAM, BS 986.5, FROM CENTER TO RT END. REMOVED AND REPLACED FLOORBEAM SECTION PER SRM.