What was found
DURING SCHEDULED D-CHECK, FOUND CORROSION ON FWD ENTRY DOOR AFT GIRT BAR ATTACH FLOOR BRACKET. REMOVED AND REPLACED GIRT ATTACH BRACKET PER MM.