What was found
DURING SCHEDULED 1/2D CHECK, FOUND AFT GALLEY DOOR FUSELAGE CUT OUT FWD FRAME CRACKED AT STRINGER 12R. REMOVED AND REPLACED FRAME SECTION PER SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED 1/2D CHECK, FOUND AFT GALLEY DOOR FUSELAGE CUT OUT FWD FRAME CRACKED AT STRINGER 12R. REMOVED AND REPLACED FRAME SECTION PER SRM.