What was found
DURING SCHEDULED D CHECK, FOUND BS 986 FLOORBEAM UPPER CHORD CORRODED, LBL 45 - RBL 45. REPAIRED FLOORBEAM PER ER 99-6052.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED D CHECK, FOUND BS 986 FLOORBEAM UPPER CHORD CORRODED, LBL 45 - RBL 45. REPAIRED FLOORBEAM PER ER 99-6052.