As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION FOUND AT KICKPLATE ANGLE DOOR SURROUND (C-CHECK RO 6/9/2023) REMOVED AND INSTALLED NEW KICKPLATE ANGLE AT DOOR SURROUND. REF CRJ-700 SRM 51-42-21-001-001-A01 AND DWG SH670-31810 REV AE. COMPLIED WITH SKYWEST TASK CARD 51-900-1002-SKY. COMPLIED WITH FORM M-337. SEE CONTINUATION FOR DETAILS.