What was found
CRACK AROUND FASTENER ON FRAME AT FS605.0 STGR18L (MARKED) (C-CHECK RO 7/30/2023) REMOVED CRACKED FRAME SECTION AT FS 605 BETWEEN STGR 17L - STGR 20L REF CRJ200 SRM 51-42-06 AND CRJ200 SRM 51-42-21 AND INSTALLED NEW FRAME SECTION P/N: 601R36026-29 AT FS 605 BETWEEN STGR 17L - STGR 20L REF CRJ200 SRM 51-42-06, CRJ200 SRM 51-42-21 AND DWG 601R36026 REV AF. REMOVED (1)EA SPLICE ANGLE AT FS 605 AND STGR 20L TO FOM REF CRJ200 SRM 51-42-06 AND INSTALLED (1)EA SPLICE ANGLE AT FS 605 AND STGR 20L REF CRJ200 SRM 51-42-06. LEAK CHECK GOOD WITH NO LEAKS NOTED.COMPLIED WITH 51-900-1003-SKY