What was found
LH FLOOR SILL HAS MULTIPLE SPOTS OF CORROSION FROM F.S. 409.00 +128 TO F.S. 559.00. (C-CHECK RO 1/22/2024) REMOVED CORROSION FROM LH FLOOR SILL FROM F.S. 409.00 +128 TO F.S. 559.00. NDT INSPECTED NO DEFECTS NOTED, APPLIED FINISHES, FOUND TO BE STRUCTURALLY ACCEPTABLE REF MHIRJ REO 601R-53-41-3208 REV - - DATED 2024-01-02, BOMBARDIER GENERIC REO 601R-53-41-666 REV -C DATED 2012-11-06, COMPLIED WITH 51-900-1003-SKY, FOR COMPLETE DETAILS OF WORK PERFORMED SEE ATTACHED CONTINUATION CARD