What was found
RH INBOARD FLAP HAS CHAFFING 2 AREAS WHERE CANOE FAIRING 683BB AND 686BB CONTACT LOWER SKIN (C-CHECK RO 4/3/2024) BLENDED-OUT DAMAGE AND EVALUATED LIMITATIONS ON RHS INBOARD FLAP LOWER SKIN AT FLAP-STA-74.718 AND FLAP STA-135.512, THE SUBJECT REWORKED CONDITION IS STRUCTURALLY ACCEPTABLE, FOUND TO BE WITHIN LIMITS.. REF REO 601R-57-52-2496 REV-- DATED 2024-02-07.COMPLIED WITH ALL STEPS SEE CONTINUATION FOR DETAILS. COMPLIED WITH SKYWEST TASK CARD 51-900-1003-SKY.