What was found
MULTIPLE SPOTS OF CORROSION NOTED ON FLOOR BEAM TOP CAP AT LBL9 BETWEEN FS409+118-FS559+10 (MARKED) (C-CHECK RO 10/26/2024) (FILED OPEN)REMOVED MULTIPLE SPOTS OF CORROSION NOTED ON FLOOR BEAM TOP CAP AT LBL9 BETWEEN FS409+118-FS559+10 REF CRJ200 SRM 51-21-06FLOOR BEAM TOP CAP PN S6830 FREE FLANGE ORIGINAL MATERIAL THICKNESS AS PER CRJ200 SRM 51-31-59-00 IS 0.05", LOWEST REMAINING MATERIAL THICKNESS IS 0.03". OUT OF LIMITS OF 10% (0.005") ALLOWABLE MATERIAL LOSS AS PER CRJ200 SRM 53-00-00-01.REMOVED AND REPLACED SEAT TRACK REF MHI REO 601R-53-41-3254 REV --, DATED 2024-08-26COMPLIED WITH TASK CARD 51-900-1003-SKY