What was found
RH PRESSURE FLOOR SILL HAS 7 SPOTS OF CORROSION ON THE TOP SURFACE. CORROSION FOUND RANGING FROM FS 449.85 TO FS 513.00 (FILED CLOSED) DURING REPAIR PROCESS EVALUATION DISCOVERED 25 TOTAL AREAS OF CORROSION DAMAGE BETWEEN FS424.00-FS559.00 AND RBL36.00-RBL45.00 AS DESCRIBED IN REO 601R-53-41-3242 REV "A" DATED 2024-07-22. REPAIRED ALL CORROSION DAMAGE AS PER REO 601R-53-41-3242 REV "A" DATED 2024-07-22. PERFORMED EDDY CURRENT INSPECTION WITH REFERENCE TO NDTM PART 1 51-20-06 AND PART 6 53-00-096 WITH NO CRACKS FOUND. COMPLETED CORROSION FINDINGS REPORT. COMPLIED WITH TASK CARD 51-900-1003-SKY. COMPLIED WITH M-337.