What was found
RH WING FUEL ACCESS PANEL 640BB, OPENING EDGE HAS PITTING AND SURFACE CORROSION ON INBOARD EDGE AND FWD OUTBOARD EDGE. (FILED CLOSED) BLENDED CORRODED AREA OF RH WING FUEL ACCESS PANEL 640BB LANDING OPENING EDGE ON INBOARD EDGE AND FWD OUTBOARD EDGE WITH REFERENCE TO REO 601R-57-21-030 REV. -L, DATED 2014-02-05. PERFORMED EDDY CURRENT INSPECTION WITH REFERENCE TO NDTM PART 1 51-20-06 AND NDTM PART 6 53-00-096 NO CRACKS FOUND. PERFORMED UT REMAINING THICKNESS INSPECTION WITH REFERENCE TO NDTM PART 4 51-00-001 AND FOUND TO BE WITHIN LIMITS OF 601R-57-21-030 REV. -L, DATED 2014-02-05. PERFORMED ROTO PEEN PROCESS TO THE RH WING FUEL ACCESS PANEL 640BB, OPENING EDGE ON INBOARD EDGE AND FWD OUTBOARD EDGE AS REQUIRED IAW REO 601R-57-21-030 REV. -L, DATED 2014-02-05. COMPLIED WITH TASK CARD 51-900-1003-SKY. COMPLIED WITH M-337. COMPLETED CORROSION FINDINGS REPORT.