What was found
SEVERAL SPOTS OF CORROSION ON THE RH PRESSURE FLOOR SILL AT FS429.00 , FS478.00 , FS501.00 , FS512.00 , (2 SPOTS) AT FS518.00 , FS524.00, FS531.00 , FS537.00 , FS542.00 , FS548.00 (FILED CLOSED) REPAIRED RH PRESSURE FLOOR SILL AT FS429.00 , FS478.00 , FS501.00 , FS512.00 , (2 SPOTS) AT FS518.00 , FS524.00, FS531.00 , FS537.00 , FS542.00 , FS548.00 WITH REFERENCE TO REO 601R-53-41-2629 REV "-B" DATED 2024-12-31. COMPLIED WITH TASK CARD 51-900-1003-SKY. COMPLIED WITH M-337. COMPLETED CORROSION FINDINGS REPORT.REFERENCE CP 29332144 AND CP 29369648 FOR EDDY CURRENT INSPECTION.REFERENCE CHILD CAMP FOR LEAK CHECK.