What was found
FOUND TOP OF AFT CARGO DOOR TRACK AT FS621.00 TO BE DAMAGED (FILED OPEN) REMOVED AND REPLACED AFT CARGO DOOR TRACK AT FS621.00 WITH REFERENCE TO SRM 51-42-06 AND SRM 51-42-21. PERFORMED EDDY CURRENT INSPECTION OF FASTENER BORES THROUGH THE ENTIRE STACK UP WITH REFERENCE TO NDTM PART 6 53-00-097 WITH NO DEFECTS FOUND. COMPLIED WITH TASK CARD 51-900-1003-SKY. COMPLIED WITH M-337. REFERENCE CP 29507519 FOR LEAK CHECK.