Service difficulty report · Overheat Loop · Cndair CL6002C10

Difficulty date
February 13, 2025
Submitted
February 14, 2025
Operation
Air carrier
Aircraft
N750SK
Make and model
Cndair CL6002C10
Aircraft serial
10207
Aircraft time
50,867 hours, 33,289 cycles
Part
Overheat Loop
Condition
Out Of Position
Location
Zone 100
Stage of operation
NR
How discovered
O
Nature of condition
N
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

TROUBLE SHOOT HISTORY OF ANTI ICE DUCT WARNINGSMCI TYPE: TROUBLESHOOTING PRIORITY 1 (FILED CLOSED) FEB 13, 2025 STATION: PHX--UPON ARRIVAL TO AIRCRAFT PERFORMED INTERROGATION OF MDC AND FOUND B1-349543, PERFORMED TROUBLESHOOTING OF ANTI-ICE DUCT WARNING IN REFERENCE WITH CRJ 700 FIM 36-21-03, UPON INSPECTION OF ANTI-ICE DUCTING UNDERNEATH CARGO AREA BETWEEN FUSELAGE STATION FS985.00 AND FS1098.20, FOUND PORTION OF LOOP B OF MT 162 TO BE SLIGHTLY TOUCHING ANTI-ICE DUCTING, ADJUSTED LOOP AS NEEDED, PERFORMED OPERATIONAL TEST OF ANTI-ICE SYSTEM IN REFERENCE WITH CRJ 700 AMM 30-11-00, COULD NO LONGER DUPLICATE FAULT CONDITION AT THIS TIME, ALL OPS CHECKS GOOD, A/C OK FOR SERVICE.