Service difficulty report · Circuit Breaker · Emb ERJ170200LR

Difficulty date
January 23, 2025
Submitted
February 18, 2025
Operation
Air carrier
Aircraft
N614CZ
Make and model
Emb ERJ170200LR
Aircraft serial
17000205
Aircraft time
40,127 hours, 25,883 cycles
Part
Circuit Breaker
Condition
Arced
Location
Zone 200
Stage of operation
IN
How discovered
9
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

L/H CIRCUIT BREAKER PANEL ARCED ON FRAME 10 BETWEEN STRINGERS 12L-13L. (C-CHECK RO 2/15/2025) REMOVED DAMAGE AND INSTALLED FABRICATED DOUBLER BEHIND L/H CIRCUIT BREAKER PANEL AT FRAME 10, BETWEEN STRINGERS 12L AND 13L REF ETD2025-170-900503, REV A. NO CHANGES TO WEIGHT AND BALANCE. SEE CONTINUATION CARD FOR ALL WORK PERFORMED.