As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
LH PRESSURE FLOOR SIL PNL IS CORRODED IN SEVERAL SPOTS FS409+128 €“ 559 (C-CHECK RO 04/17/2025)REMOVED CORROSION BY BLENDING AT BLENDS #3, #4, #5, #6. FOUND TO BE WITHIN LIMITS. REF REO 601R-53-41-666 REV C DATED 2012-11-06. REPAIRED BLENDS #1 AND #2. REF REO 601R-53-41-3297, REV --, DATED 2025-03-13. PERFORMED PRESSURE LEAK CHECK OF THE LH SIDE PRESSURE FLOOR SILL PANEL BETWEEN FS409+128-FS559.00. LEAK CHECK PASSED. COMPLIED WITH SKYWEST TASK CARD 51-900-1003-SKY.