What was found
LH WING FLAP TRACK 2 OB HAS DEPTH REDUCTION THAT EXCEEDS 0.549 INCH IN LENGTH AND IS OUT OF LIMITS. (C-CHECK RO 08/09/2025)REMOVED AND REPLACED THE LH INBOARD FLAP MAIN TRACK #2 O/B REF. AMM 57-54-23. ASSET#: TC1-609 CAL: 03/06/26, ASSET#: TC2-10406 CAL: 06/19/26 ASSET#: TC2-10240 CAL: 3-19-26 PO#: 325436 ,322771, 308353