What was found
CORROSION FOUND ON STR21R STRINGER SPLICE AT FS333. REMOVED AND INSTALLED NEW STRINGER 21R SPLICE AT FS333 IAW SRM 51-42-06-001-001 A01 AND DWG SH670-32420 REV E, LEAK CHECK PASSED. COMPLIED WITH TASK 51-900-1002-SKY.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FOUND ON STR21R STRINGER SPLICE AT FS333. REMOVED AND INSTALLED NEW STRINGER 21R SPLICE AT FS333 IAW SRM 51-42-06-001-001 A01 AND DWG SH670-32420 REV E, LEAK CHECK PASSED. COMPLIED WITH TASK 51-900-1002-SKY.