As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
RH FWD EMER DOOR HAS SUSPECTED CRACK AT UPPER AFT STOP. (MARKED) (C-CHECK RO 09/07/2025)PERFORMED REPAIR OF THE RH FWD EMERGENCY EXIT DOOR FRAME LOCATED AT THE BASE OF THE AFT PROXIMITY SENSOR STRIKER AS PER REO 670-52-21-103 REV --, 2024-11-06. SEE CONTINUATION CARD FOR FURTHER DETAILS. COMPLIED WITH TASK CARD 51-900-1002-SKY.