What was found
LH AFT EMER EXIT DOOR HAS CHAFES AROUND 2EA FASTENER HOLES BELOW WINDOW. (MARKED) (C-CHECK RO 09/07/2025)PERFORMED A BLEND REPAIR AND FOUND WITHIN LIMITS PER REO 690-52-21-190 REV. -- DATED 2025-04-12.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LH AFT EMER EXIT DOOR HAS CHAFES AROUND 2EA FASTENER HOLES BELOW WINDOW. (MARKED) (C-CHECK RO 09/07/2025)PERFORMED A BLEND REPAIR AND FOUND WITHIN LIMITS PER REO 690-52-21-190 REV. -- DATED 2025-04-12.